Conformity assessment under the CRA: module A, B + C or H
11 min read
Before a product with digital elements is placed on the market, the manufacturer has to demonstrate that it meets the essential cybersecurity requirements. The Cyber Resilience Act provides four routes for this: internal control, EU-type examination followed by conformity to type, full quality assurance and European cybersecurity certification. This guide shows what the procedures require and when a notified body has to be involved.
Four procedures at a glance
Conformity assessment is the process of verifying whether the essential cybersecurity requirements set out in Annex I have been fulfilled (Art. 3(27)). It covers the product and the processes put in place by the manufacturer – such as vulnerability handling. Art. 32(1) lists four routes:
- the internal control procedure (based on module A) set out in Annex VIII, Part I – the manufacturer assesses itself,
- the EU-type examination procedure (module B) set out in Annex VIII, Part II, followed by conformity to EU-type based on internal production control (module C) set out in Annex VIII, Part III – with a notified body,
- a conformity assessment based on full quality assurance (module H) set out in Annex VIII, Part IV – with a notified body,
- where available and applicable, a European cybersecurity certification scheme pursuant to Art. 27(9).
Source: Art. 3(27) CRA · Art. 32(1) CRA · Annex VIII CRA
Which procedure applies to which product class
Which procedures are permitted depends on how the product is classified. Our guide “Important and critical products under the Cyber Resilience Act” explains which products are important (Annex III, class I or II) or critical (Annex IV). For the procedures:
- All other products: free choice among the four procedures in Art. 32(1) – including internal control without a notified body.
- Class I: internal control is sufficient only where the manufacturer has applied harmonised standards, common specifications or European cybersecurity certification schemes at assurance level at least ‘substantial’ as referred to in Art. 27. Where it has not applied them or only in part, or where they do not exist, module B followed by module C or module H applies with regard to the requirements concerned (Art. 32(2)).
- Class II: module B followed by module C, module H or – where available and applicable – a European cybersecurity certification scheme at assurance level at least ‘substantial’ (Art. 32(3)). Internal control is not provided for.
- Critical products: a European cybersecurity certification scheme in accordance with Art. 8(1). Where its conditions are not met, the procedures for class II apply (Art. 32(4)).
Art. 8(1) empowers the Commission to determine by delegated act which critical products are required to obtain a European cybersecurity certificate at assurance level at least ‘substantial’. As long as no such act has been adopted, these products are subject to the procedures in Art. 32(3).
Exception for free and open-source software: where it falls under a category in Annex III, the manufacturer may use any procedure in Art. 32(1) – including internal control – provided that the technical documentation referred to in Art. 31 is made available to the public when the product is placed on the market (Art. 32(5)).
Source: Art. 32(1) to (5) CRA · Art. 8(1) CRA
Module A: internal control
Under internal control, the manufacturer declares on its sole responsibility that the product meets the requirements in Annex I, Part I, and that it meets the vulnerability handling requirements in Annex I, Part II. No notified body is involved. The manufacturer
- draws up the technical documentation described in Annex VII,
- takes all measures necessary so that design, development, production and vulnerability handling, and their monitoring, ensure compliance with Annex I, Parts I and II,
- affixes the CE marking to each compliant product,
- draws up a written EU declaration of conformity in accordance with Art. 28 and keeps it together with the technical documentation at the disposal of the national authorities for 10 years after placing on the market or for the support period, whichever is longer.
Marking and declaration may be handled by an authorised representative on the manufacturer’s behalf and under its responsibility, provided this is specified in the mandate.
Source: Annex VIII, Part I CRA
Module B + C: EU-type examination and conformity to type
In EU-type examination (module B), a notified body examines the technical design and development of the product and the manufacturer’s vulnerability handling processes. It examines the technical documentation and supporting evidence as well as specimens of one or more critical parts of the product.
- Application: with a single notified body of your choice, including a written declaration that it has not been lodged with any other body.
- Documents: the technical documentation, including an adequate analysis and assessment of the risks, and supporting evidence. The evidence has to mention any documents that have been used – in particular where harmonised standards or technical specifications have not been applied in full. Where necessary, it includes test results from a laboratory.
- Examination: where the manufacturer has applied standards or specifications, the body checks that they have been applied correctly; where not, it checks whether the manufacturer’s own solutions meet the requirements.
- Outcome: an evaluation report and, if successful, an EU-type examination certificate. The body releases the content of the report only with the manufacturer’s agreement. It gives detailed reasons for any refusal.
- Afterwards: the body carries out periodic audits to ensure that the vulnerability handling processes are implemented adequately. The manufacturer reports modifications to the approved type or to those processes that may affect conformity; they require an addition to the certificate.
Module C follows module B: through production and its monitoring, the manufacturer ensures that each product conforms to the type described in the certificate, affixes the CE marking and draws up a written declaration of conformity for each product model. It keeps the certificate, declaration and technical documentation for 10 years after placing on the market or for the support period, whichever is longer.
Source: Annex VIII, Parts II and III CRA
Module H: full quality assurance
Under module H, the notified body does not examine a single type but the manufacturer’s quality system for the design, development, final product inspection and testing of the products and for handling vulnerabilities. The manufacturer maintains its effectiveness throughout the support period.
- Application: with a notified body of your choice, including the technical documentation for one model of each product category, the quality system documentation and the declaration that the application has not been lodged with any other body.
- Documentation: written policies, procedures and instructions – covering among other things quality objectives and responsibilities, the standards applied, design and development control and verification, examinations and tests before, during and after production and quality records.
- Audit: with at least one member experienced as an assessor in the product field and technology, including an assessment visit to your premises, where such premises exist.
- Surveillance: periodic audits by the body. You report intended changes to the quality system in advance; the body decides whether a reassessment is necessary.
- Marking: CE marking and – under the responsibility of the notified body – its identification number on each product; a written declaration of conformity for each product model.
Source: Annex VIII, Part IV CRA
Harmonised standards, common specifications, certification
For class I, these three instruments decide whether internal control is permitted. They work through the presumption of conformity under Art. 27:
- Harmonised standards whose references have been published in the Official Journal of the European Union: conformity is presumed in so far as the standards cover the requirements (Art. 27(1)).
- Common specifications: the Commission may establish them by implementing act, but only under conditions – for example where harmonised standards are not delivered on time and no reference has been published in the Official Journal. They too give rise to a presumption in so far as they cover the requirements (Art. 27(2) and (5)).
- European cybersecurity certification schemes under Regulation (EU) 2019/881: a certificate or EU statement of conformity issued under them gives rise to a presumption in so far as it covers the requirements (Art. 27(8)). The Commission specifies by delegated act which schemes can be used. A certificate issued under such a scheme at assurance level at least ‘substantial’ eliminates the obligation to carry out a third-party conformity assessment under Art. 32(2) and (3) for the corresponding requirements (Art. 27(9)).
Status according to our research of 2 Oct 2026 (standards radar): no harmonised standard under the Cyber Resilience Act has yet been published in the Official Journal. For class I, this leaves only the route via a notified body for now, unless a common specification or suitable certification applies. Check the current status before you decide.
Source: Art. 27(1), (2), (5), (8), (9) CRA · Art. 32(2) and (3) CRA
Who the notified bodies are
A notified body is a conformity assessment body that a Member State has notified to the Commission and the other Member States for assessments under the Cyber Resilience Act (Art. 3(29), Art. 35(1)). What matters for you as a manufacturer:
- Independence: the body is a third party. It may not be involved in the design, development or distribution of the products it assesses, nor engage in activities that may conflict with its independence – this applies in particular to consultancy services (Art. 39(3) and (4)).
- Proportionality: the bodies avoid unnecessary burdens and take due account of the size, sector, structure and complexity of the undertaking, the cybersecurity risk of the product and the mass or serial nature of production (Art. 47(2)). The degree of rigour remains (Art. 47(3)).
- Shortcomings: where the manufacturer has not met the requirements, the body requires corrective measures and does not issue a certificate. It may restrict, suspend or withdraw certificates already issued (Art. 47(4) to (6)).
- Appeal: Member States ensure that an appeal procedure against decisions of notified bodies is available (Art. 48).
The rules on notified bodies (Chapter IV, Articles 35 to 51) have applied since 11 June 2026 (Art. 71(2)). By 11 December 2026, Member States shall strive to ensure that there is a sufficient number of notified bodies in the Union (Art. 35(2)).
Status according to our check of 4 Nov 2026: the Commission’s NANDO database did not yet list any active notified body under Regulation (EU) 2024/2847. You will find the current list in NANDO.
Source: Art. 3(29) CRA · Art. 35 CRA · Art. 39(3) and (4) CRA · Art. 47 CRA · Art. 48 CRA · Art. 71(2) CRA · Commission NANDO database: notified bodies under Regulation (EU) 2024/2847
Fees and relief for small companies
- When fees for conformity assessment are set, the specific interests and needs of microenterprises and small and medium-sized enterprises, including start-ups, are taken into account; the fees are reduced proportionately (Art. 32(6), Art. 39(12)). The Regulation does not state any amounts.
- Microenterprises and small enterprises may provide the technical documentation in a simplified format that the Commission specifies by implementing act; notified bodies have to accept that form (Art. 33(5)).
- Member States support, where appropriate, testing and conformity assessment activities of microenterprises and small enterprises (Art. 33(1)(c)).
Source: Art. 32(6) CRA · Art. 39(12) CRA · Art. 33(1) and (5) CRA
The basis for every procedure: technical documentation
Before placing the product on the market, the manufacturer draws up the technical documentation, carries out the chosen conformity assessment procedure or has it carried out, and then draws up the EU declaration of conformity (Art. 13(12)). The documentation contains at least the elements set out in Annex VII and is continuously updated at least during the support period (Art. 31(1) and (2)).
Under module A, it stays with the manufacturer. Under module B, it is part of the application; under module H, it is submitted for one model of each product category. Documentation and correspondence relating to the procedure are drawn up in an official language of the Member State in which the notified body is established or in a language acceptable to that body (Art. 31(4)).
Source: Art. 13(12) CRA · Art. 31(1), (2) and (4) CRA · Annex VIII, Parts II and IV CRA
Key dates
- Since 11 June 2026: rules on the notification of conformity assessment bodies (Chapter IV).
- By 11 December 2026: Member States shall strive to ensure a sufficient number of notified bodies.
- From 11 December 2027: the rest of the Regulation applies – including the obligation to carry out the conformity assessment before placing on the market.
Source: Art. 71(2) CRA · Art. 35(2) CRA
In practice
- Clarify the classification of your product first. For most products, internal control is sufficient – then you need no notified body, but complete technical documentation.
- If your product falls under class I, plan for a notified body as long as no harmonised standard has been published in the Official Journal. Keep an eye on standardisation: with a fully applied standard, internal control may become possible later.
- For class II and critical products, there is no way around a third-party assessment. Contact bodies early – the number of notified bodies has so far been small.
- Module B tends to suit you if you have a few clearly defined product types. Module H may pay off if you develop many products under a common quality system and already run a documented quality management system.
- Do not expect advice on your product from the notified body – it has to remain independent. Prepare the documents yourself or get support from elsewhere.
- Expect ongoing effort under B and H: periodic audits of vulnerability handling or of the quality system, and reporting of changes.
Checklist: do I need a notified body?
- Does my product have the core functionality of a category in Annex III or IV? If not: internal control is possible.
- Is it free and open-source software and do I publish the technical documentation when placing it on the market? If so: internal control is possible.
- Class I: do I fully apply a harmonised standard published in the Official Journal, a common specification or a certification at assurance level at least ‘substantial’ for all requirements? If so: internal control is possible; otherwise a notified body.
- Class II or critical: notified body (module B + C or H) or European cybersecurity certification.
- Technical documentation complete, in a language the body accepts and including the risk assessment?
Related guides
- Product and evidenceImportant and critical products under the Cyber Resilience Act3 min read
- Product and evidenceTechnical documentation under the Cyber Resilience Act7 min read
- Product and evidenceEU declaration of conformity under the Cyber Resilience Act4 min read
- FundingSMEs and the Cyber Resilience Act: relief and support4 min read
- Economic operatorsOpen source and the Cyber Resilience Act: who has which obligations8 min read
- Product and evidenceAnnex I CRA: the essential cybersecurity requirements10 min read
Terms in the Cyber Resilience Act glossary
Sources
- Regulation (EU) 2024/2847, Art. 3, 8, 13, 27, 31 to 33, 35, 39, 47, 48, 71, Annex VIII (EUR-Lex, Official Journal)
- Commission NANDO database: notified bodies under Regulation (EU) 2024/2847
First published 9 Nov 2026, last updated 9 Nov 2026. This guide reflects the wording of the regulation and the Commission’s guidelines and does not constitute legal advice.